SBE Electric Heating & Cooling 267.480.7080
  • Home
  • Heating
    • Electric Heating
    • Gas Heating
    • Heat Pumps
    • Oil Heating
    • Propane Heating
  • Cooling
    • Central Air Conditioning System
    • Rooftop HVAC Systems
  • Electrical
  • Manuals
    • Aprilaire
    • Bosch
    • Bryant
      • Bryant Condenser Obsolete
      • Bryant Furnace
      • Bryant Obsolete
      • Bryant Startup
      • BRYANT TROUBLESHOOTING
    • BURNHAM
    • ECOBEE
    • EMERSON WHITE RODGERS
    • FUJITSU MINI SPLIT DUCTLESS
    • GIBSON
    • GOODMAN
    • HONEYWELL
    • INTERMATIC
    • LENNOX
    • THERMOPRIDE
    • TOTALINE THERMOSTAT
    • TRANE
    • WHIRLPOOL
    • WIRING DIAGRAMS
  • Generators
20
Jan

G71-MPP series Lennox furnace shut down. Error code flashing E228 Read more: G71-MPP series Lennox furnace shut down. Error code

G71-MPP series Lennox furnace shut down. Error code flashing E228  Read more: G71-MPP series Lennox furnace shut down. Error code

G71MPP series units are high−efficiency multi−position
(upflow, downflow, horizontal right and left) gas furnaces
equipped with variable capacity gas valve, variable speed
combustion air inducer and variable speed indoor blower
motor. All models are designed only for direct vent (dual
pipe) venting system. G71MPP units are available in heating
capacities from 66,000 to 132,000 Btuh (19.3 to 38.6
kW) and cooling applications from 2 to 5 tons (7.0 kW to
17.5 kW). Refer to Engineering Handbook for proper sizing.
Units are factory equipped for use with natural gas. Kits are
available for conversion to LPG operation. G71MPP model
units are equipped with the Lennox SureLight® variable capacity
integrated control. All G71MPP units meet the California
Nitrogen Oxides (NOx) Standards and California Seasonal
Efficiency requirements.

LED 7 Segment Status / Error Code
Press the diagnostic push button and hold it to cycle through a menu of options. Every five seconds a new menu item will be
displayed. Release the button when the desired mode is displayed.
When the solid “E” is displayed, the control enters the Error Code Recall mode. Error Code Recall mode menu options: No change (displaying
error history) remains in Error Code Recall mode; solid “≡” exits Error Code Recall mode; and solid “c” clears the error history. Must
press button while flashing “c” is displayed to clear error codes.
When the solid “−” is displayed, the control enters the Field Test mode. Field Test mode menu options: Solid “C” starts pressure switch
calibration; blinking *−” exits Field Test mode.
Flash Code Diagnostic Code / Status of Furnace
* Idle mode (Decimal blinks at 1 Hz 1/2 sec. On and 1/2 sec. Off
A CFM Display (1 sec. On 1/2 sec Off, CFM value)
C Staged Cooling (1 sec. On 1/2 sec. Off or 2 Stage 1 sec. pause CFM pause, Repeat codes)
d Dehumidification Mode (1 sec. On 1 sec Off, CFM, Pause Repeat Codes)
h Variable Capacity Heat (1 sec On 1/2 sec Off % of input rate Pause CFM Pause Repeat Codes)
H Staged Heat (1 sec On 1/2 sec Off or 2 Stage 1 sec, CFM Pause Repeat Codes)
110 Low Line Voltage
113 High Line Voltage
115 Low 24V (control will restart if the error recovers)
125 Control failed self check, internal error, failed hardware. Control will restart if error recovers
180 Outdoor Air Sensor Failure − no error if just disconnected, only show if shorted or out of range
200 Rollout circuit open or previously opened
201 Circulator / COM failure − unable to communicate w / circulating motor (blower)
202 Circulating motor / resistor mis−match or resistor missing
204 Gas Valve Miswired − Resume normal operation after error corrected
223 Low Pressure Switch Failed Open
224 Low Pressure Switch Failed Closed
225 High Pressure Switch Failed Open
226 High Pressure Switch Failed Closed
227 Low Pressure Switch Opened during TFI or Run mode
228 Unable to perform successful pressure switch calibration mode
240 Low Flame Mode − Run Mode
241 Flame sense out of sequence − flame still present
250 Limit switch circuit open
270 Watchguard − Exceed maximum number of retries. No flame current sensed
271 Watchguard − Exceed maximum number ignition retries where the last retry was due to pressure switch
opening
272 Watchguard − Exceed maximum number of recycles where the last recycle was due to pressure switch
opening
273 Watchguard − Exceed maximum number of recycles where the last retry was due to flame failure
274 Watchguard − The limit remained open longer than 3 minutes
275 Watchguard − Flame sensed out of sequence; flame signal gone
290 Ignitor circuit Fault − failed ignitor or triggering circuitry
291 Restricted airflow − available CFM below min. firing rate
292 Circulator motor unable to start (seized bearings, stuck wheel, etc)
294 Inducer motor amp draw too high
310 Discharge air sensor failure − no error if just disconnected, only show if shorted or out of range
311 Restricted airflow heating mode − target input rate reduced to match available circulator CFM
312 Restricted airflow cooling or continuous fan mode − information only

{module Googleadlinks}

{module AdSense unit: 336×280}

Find Lennox G71MPP Service Facts for troubleshooting flow chart. Uploading Shortly

http://www.justanswer.com/hvac/4fedw-g71-mpp-series-lennox-furnace-new-2009-shut-down-error-code.html

  • 0

There are no comments so far

Leave a Comment

Don't worry. We never use your email for spam.

Don't worry. We never use your email for spam.

SBE On Pinterest

Latest Posts

  • Securing your new Samsung Galaxy S4 Phone May 7, 2013
  • TROUBLESHOOTING SAMSUNG WASHING MACHINE WA422PRHDWR/AA Odor May 3, 2013
  • SAMSUNG WASHING MACHINE WA400PJHDWR/AA Clanking Noise When The Drum Is Moved By Hand May 3, 2013
  • SAMSUNG WASHING MACHINE WA400PJHDWR/AA Washer Makes Clicking Noises May 3, 2013
  • TROUBLE SHOOTING SAMSUNG WASHING MACHINE WA400PJHDWR/AA Odor May 3, 2013
  • Huntsville Alabama 35808 Heating and Air Conditioning Service Repair and Installation April 15, 2013
  • Huntsville Alabama 35807 Electric Heating and Air Conditioning Service Repair and Installation April 15, 2013
  • Huntsville Alabama 35806 Electric Heating and Air Conditioning Service Repair and Installation April 15, 2013
  • Huntsville Alabama 35805 Electric Heating and Air Conditioning Service Repair and Installation April 15, 2013
  • Huntsville Alabama 35804 Electric Heating and Air Conditioning Service Repair and Installation April 15, 2013
  • Huntsville Alabama 35803 Electric, Heating and Air Conditioning Service Repair and Installation April 14, 2013
  • Huntsville Alabama 35802 Electric, Heating and Air Conditioning Service Repair and Installation April 14, 2013

Comments

  • SBE ELECTRIC HEATING AND COOLING on DOWNLOAD FUJITSU MINI SPLIT DUCTLESS MANUALS
  • rich on DOWNLOAD FUJITSU MINI SPLIT DUCTLESS MANUALS
  • SBE ELECTRIC HEATING AND COOLING on Philadelphia PA SBE Electric Heating and Air Conditioning REPAIR (19111)
  • 1F80-361 White-Rodgers 80 Series® Single Stage Thermostat White Rodgers Manuals (Emerson Climate Technologies) « SBE on Heating and Air conditioning Sbe Electric Heating and Cooling. Contact Us At 267-480-7080
  • SBE Electric Heating Cooling Serves The Following Areas « SBE on Horsham PA Electric, Heating and Air Conditioning (19044)

Archives

  • May 2013 (5)
  • April 2013 (10)
  • March 2013 (5)
  • February 2013 (9)
  • December 2012 (2)
  • November 2012 (1)
  • August 2012 (1)
  • July 2012 (4)
  • April 2012 (3)
  • March 2012 (12)
  • January 2012 (147)
  • December 2011 (13)
  • November 2011 (77)
  • October 2011 (12)
  • September 2011 (9)
  • August 2011 (16)
  • June 2011 (40)
  • May 2011 (97)
  • April 2011 (1)
  • March 2011 (4)
  • February 2011 (16)
  • January 2011 (252)
  • December 2010 (2)
  • January 2009 (1)
  • November 1999 (695)

Translation


 Edit Translation

Categories

Tags

267-480-7080 ac ac installation ac repair air conditioner contractors air conditioner repair air conditioner service air conditioning air conditioning companies air conditioning contractor air conditioning contractors air conditioning installers air conditioning repair company air conditioning repair service air conditioning repair services air conditioning service air conditioning service & repair air conditioning services central ac installer central ac repair central ac service central air conditioner repair central air repair commercial ac repair cooling cooling contractor Coupon discount electric Furnace Repair Heater Service Heating heat pump heatpump How to hvac installation PA repair residential ac repair residential air conditioner repair save service service call Thermostat
Copyright 2012 - 2013 · SBE Electric Heating and Cooling
  • /Appliance Repair
  • /Appliance Tips
  • /Boilers
  • /Brands
  • /California
  • /Chevy Volt
  • /Coupons
  • /Ecobee
  • /Electric Energy
  • /Error codes
  • /For the Trade
  • /Honeywell Thermostats
  • /How To
  • /HVAC
  • /Heating
  • /Lighting
  • /LED Under Cabinet Lighting
  • /AC Condenser Manuals
  • /Download | Wiring Diagrams at SBE Electric Heating and Cooling
  • /Furnace Diagnostic and Error Codes
  • /Heat Pump Diagnostic and Error Codes
  • /Honeywell Humidifiers
  • /Honeywell-UV-Lights
  • /Alabama
  • /Alaska
  • /Arizona
  • /Arkansas
  • /Colorado
  • /Florida
  • /Apps
  • /Electrical Resources
  • /Bosch Tankless Water Heater Diagnostic and Error Codes
  • /Bryant Furnace Diagnostic and Error Codes
  • /Goodman Furnace Diagnostic and Error Codes
  • /Lennox Furnace Diagnostic and Error Codes

Download

Close